Special Service ToolWork Procedure
Perform the following procedures after replacing the around view monitor control unit.
REPLACE AROUND VIEW MONITOR CONTROL UNIT
Replace around view monitor control unit. Refer to Removal and Installation.
>>
GO TO 2.
WRITING MAC KEY
With CONSULT
Perform MAC key writing. Refer to Description. ...
Work Procedure
DESCRIPTION
The purpose of the operation inspection is to check that the individual system operates normally.
Check condition : Engine running at normal operating temperature.
OPERATION INSPECTION (DISPLAY UNIT)
CHECK MEMORY FUNCTION
Touch AUTO switch to activate air conditioning.
Set temperatur ...
NVH Troubleshooting Chart
Possible cause and SUSPECTED PARTS Symptom Reference DRIVE SHAFT FRONT AXLE Noise Shake Noise Shake Vibration Shimmy Judder Poor quality ride or handling Excessive joint angle × × — — — — — — Inspection Joint sliding resistance × — — — — — — ...