When each power window motor replaced, the initialization is necessary for normal operation of power window system. Refer to Work Procedure.
CAUTION:
The following specified operations cannot be performed under the non-initialized condition.
Auto-up operation
Anti-pinch function
Work Flow
Work ProcedureDiagnosis Procedure
PERFORM "ALL SELF-DIAGNOSIS"
With CONSULT
Perform “All DTC Reading” using CONSULT.
Is any DTC detected?
YES>>
GO TO 2.
NO>>
GO TO 3.
REPAIR MALFUNCTIONING PARTS
Repair all detected DTCs according to the diagnosis procedure.
Perform “All DTC Reading” using CONSULT again.
Check t ...
Removal and Installation
REMOVAL
Disconnect the battery cable from the negative terminal. Refer to Exploded View.
CAUTION:
To prevent damage to the parts, disconnect the battery cable from the negative terminal first.
Remove the battery positive terminal cover.
Remove positive cable mounting nuts , and then disconnect the ...
LIQUID GASKET
REMOVAL OF LIQUID GASKET SEALING
After removing mounting nuts and bolts, separate the mating surface using the seal cutter [SST: KV10111100 (NI-37228)] (A) and remove old liquid gasket sealing.
CAUTION:
Never damage the mating surfaces.
Tap the seal cutter [SST: KV10111100 (NI-37228)] to insert it ...