Symptom Table
Work FlowChanging
WARNING:
Recommended fluid and fluid capacity Refer to Fluids and Lubricants.
CAUTION:
Use only recommended A/T fluid. Never mix with other A/T fluid.
Start the engine.
Adjust the A/T fluid temperature to be approximately 50°C (122°F).
NOTE:
Check with “Fluid temperature” in “TRANSMISS ...
Inspection Procedure
INSTRUMENT PANEL
Most incidents are caused by contact and movement between:
Cluster lid A and instrument panel
Acrylic lens and combination meter housing
Instrument panel to front pillar garnish
Instrument panel to windshield
Instrument panel mounting pins
Wiring harnesses behind the combination met ...
Work Flow
OVERALL SEQUENCE
DETAILED FLOW
INTERVIEW FOR MALFUNCTION
It is also important to clarify the customer concerns before starting the inspection. Interview the customer about the concerns carefully and understand the symptoms fully.
NOTE:
The customers are not professionals. Never assume that “mayb ...