Exploded View

![]() |
Instrument finisher B | ![]() |
Advanced ambient light (instrument panel passenger side) | ![]() |
Indirect light RH |
![]() |
: Pawl | ||||
| : vehicle front | |||||
Removal and Installation
CAUTION:
Disconnect the battery negative terminal or remove power circuit fuse when performing the operation for preventing electric leakage. Refer to Precautions for Removing Battery Terminal.
REMOVAL
Remove instrument pad B. Refer to Removal and Installation.
Disconnect harness connector.
Remove indirect light RH fixing screws
, and then remove indirect light RH.

Disengage advanced ambient light (instrument panel passenger side) fixing pawls using a remover tool (A), and then remove advanced ambient light (instrument panel passenger side).

![]() |
: Pawl |
INSTALLATION
Install in the reverse order of removal.
Replacement
CAUTION:
-
Disconnect the battery negative terminal or remove power circuit fuse when performing the operation for preventing electric leakage. Refer to Precautions for Removing Battery Terminal.
-
Replacement of bulb is not possible due to the adoption of LED. When replacement, replace advanced ambient light (instrument panel passenger side) as a single part. Refer to Removal and Installation.
Other materials
Precautions
Precautions for Removing Battery Terminal
When disconnecting the 12V battery terminal, turn off the ACC power before disconnecting the 12V battery terminal, observing “How to disconnect 12V battery terminal� described below.
NOTE:
Some ECUs operate for a certain fixed time even after ignit ...
Curtain Air Bag Module
Exploded View
Curtain airbag module
: N·m (kg-m, ft-lb)
Removal and Installation
WARNING:
Always observe the following items for preventing accidental activation.
Before servicing, ignition switch OFF, disconnect 12V battery negative terminal and wait for 3 mi ...
P Range Interlock Door Unlock Function Does Not Operate
Diagnosis Procedure
CHECK “AUTO DOOR UNLOCK� SETTING IN COMBINATION METER
Check “Auto Door Unlock� setting is “Shift to P�.
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Set “Shift to P� in combination meter.
REPLACE BCM
Replace BCM. Refer to Removal and Instal ...