DESCRIPTION
If only the around view monitor control unit is replaced, the calibration data stored in the camera can be written to the around view monitor control unit by selecting "Camera Calibration" of "Work Support" mode in CONSULT.
WORK PROCEDURE
WRITE CALIBRATION DATA
With CONSULT
Select "CALIBRATING CAMERA IMAGE" of "Work Support" mode using CONSULT.
After displaying the status, check that the status is displayed as "Normal".
Is the status of each camera displayed as "Normal"?
YES>>INSPECTION END
NO>>Calibrate the camera that is not displayed as "normal". Refer to Work Procedure.
Inspection of Welded Portion
Spot welded portions can be checked by the destructive inspections explained below. They can be easily adopted when welding. Before and after welding, you should perform these destructive inspections to check the strength of the welded portions.
The welding spots should be equally spaced and arrange ...
Disassembly and Assembly
DISASSEMBLY
Fix shaft with a vise.
CAUTION:
Protect shaft when fixing with a vise using aluminum or copper plates.
Remove circular clip from housing.
Remove dust shield from housing.
Remove boot bands, and then remove boot from housing.
Put matching marks on housing and shaft.
CAUTION:
Use paint o ...
ENGINE COOLANT : Draining
WARNING:
WARNING:
To avoid being scalded, never change engine coolant when the engine is hot.
Wrap a thick cloth around reservoir tank cap and carefully remove reservoir tank cap.
First, turn reservoir tank cap a quarter of a turn to release built up pressure. Then turn reservoir tank cap all the wa ...