Front Air Conditioner
Description
Symptom
-
Insufficient cooling
-
No cool air comes out. (Air flow volume is normal.)
Diagnosis Procedure
NOTE:
Perform self-diagnoses with CONSULT before performing symptom diagnosis. If any DTC is detected, perform the corresponding diagnosis.
CHECK MAGNET CLUTCH OPERATION
-
Ignition switch ON.
-
Touch fan switch and operate front blower fan.
-
Touch A/C switch.
-
Check visually and by sound that compressor operates.
-
Touch A/C switch again.
-
Check that compressor stops.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Perform diagnosis of “COMPRESSOR DOES NOT OPERATE� in “SYMPTOM DIAGNOSIS�. Refer to Diagnosis Procedure.
CHECK DRIVE BELT
Check tension of drive belt. Refer to Inspection.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Adjust or replace drive belt depending on the inspection results.
CHECK REFRIGERANT CYCLE PRESSURE
Connect recovery/recycling recharging equipment to the vehicle and perform pressure inspection with gauge. Refer to Symptom Table.
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace parts depending on the inspection results.
CHECK ECV
Perform ECV circuit diagnosis. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair or replace parts depending on the inspection results.
CHECK AIR LEAKAGE FROM EACH DUCT
Check duct and nozzle, etc. of the air conditioning system for leakage.
Is the inspection result normal?
YES>>GO TO 6.
NO>>Repair or replace parts depending on the inspection results.
CHECK SUNLOAD SENSOR
Perform sunload sensor diagnosis. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>GO TO 7.
NO>>Repair or replace parts depending on the inspection results.
CHECK SETTING OF TEMPERATURE SETTING TRIMMER
-
Check setting value of temperature setting trimmer. Refer to CONSULT Function.
-
Check that temperature setting trimmer is set to “+ direction�.
NOTE:
The control temperature can be set with the setting of the temperature setting trimmer.
-
Set difference between the set temperature and control temperature to “0�.
Is inspection result normal?
YES>>INSPECTION END
NO>>Replace A/C auto amp. Refer to Removal and Installation.
Rear Air Conditioner
Description
Symptom
-
Insufficient cooling
-
No cool air comes out. (Air flow volume is normal.)
Diagnosis Procedure
NOTE:
Perform self-diagnoses with CONSULT before performing symptom diagnosis. If any DTC is detected, perform the corresponding diagnosis.
CHECK REFRIGERANT CYCLE PRESSURE
Connect recovery/recycling recharging equipment to the vehicle and perform pressure inspection with gauge. Refer to Symptom Table.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace parts depending on the inspection results.
CHECK AIR LEAKAGE FROM EACH DUCT
Check duct and nozzle, etc. of the air conditioning system for leakage.
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace parts depending on the inspection results.
CHECK SUNLOAD SENSOR
Check sunload sensor diagnosis. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>INSPECTION END
NO>>Repair or replace parts depending on the inspection results.
Other materials
Drive Plate
Exploded View
Crankshaft position sensor
Dowel pin
Drive plate
: N·m (kg-m, ft-lb)
: N·m (kg-m, in-lb)
Removal and Installation
REMOVALRemove A/T assembly from the vehicle. Refer to following :
2WD models: Refer to Removal and Installation.
4WD models: Refer to Removal and ...
Easy Fill Tire Alert Does Not Activate
Description
The easy fill tire alert does not function while inflating a tire when the selectposition is in P-range with the ignition switch ON or with the engine started.NOTE:
After starting to inflate the tire, it takes a few seconds for the easy fill tire alert to function.
If there is no r ...
Diagnosis and Repair Workflow
Work Flow
OVERALL SEQUENCEDETAILED FLOWGET INFORMATION FOR SYMPTOM
Get detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurs).
Check operation condition of the function that is malfunctioning.
>>
GO TO 2.
CHECK ...