Unit: kPa (kg/cm2, psi)
| Reservoir tank cap relief pressure | Standard | 118 (1-2/8,17-1/8) | |
| Limit | 108.2 (1-1/8,15-6/8) | ||
| Leakage testing pressure | 186 (1-7/8,27) | ||
RadiatorHow to Use Hammer and Dolly
(1) HAMMER-ON-DOLLY
This is also known as dinging on the dolly. The dolly is held directly under the area being struck with the hammer. Hammering smoothes the dented metal between the dolly and hammer. This method causes the sheet metal to stretch.
Hammering on a dolly is most effective for repairi ...
Removal and Installation
REMOVAL
Remove back door trim. Refer to Removal and Installation.
Remove mounting nuts .
Remove mounting bolts .
Disconnect rear washer tube C .
CAUTION:
When washer tube is disconnected, washer fluid may come out so prepare a container to receive washer fluid and never allow washer fluid to b ...
Removal and Installation
REMOVAL
CAUTION:
When removing, always use a remover tool that is made of plastic.
Remove center ventilator grille.Remove fixing screw .
Disengage fixing pawls.
: Pawl
Disengage fixing pawls, and then remove center ventilator grille.
: Pawl
INSTALLATION
Install in the reverse order of rem ...