Description
Differential lock indicator lamp does not turn ON when turning differential lock mode switch to “ON” after engine start.
Diagnosis Procedure
CHECK SELF-DIAGNOSTIC RESULTS
With CONSULT
Perform self-diagnosis for “DIFFERENTIAL LOCK”.
Is any DTC detected by self-diagnosis?
YES>>Check the malfunctioning system. Refer to DTC Index.
NO>>GO TO 2.
CHECK DIFFERENTIAL LOCK MODE SWITCH OPERATION
Check differential lock mode switch circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES >>GO TO 3.
NO>>Repair or replace the error-detected parts.
CHECK DIFFERENTIAL LOCK CONTROL UNIT POWER SUPPLY AND GROUND CIRCUIT
Check differential lock control unit power supply and ground circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
YES>>Replace the differential lock control unit. Refer to Removal and Installation.
NO>>Repair or replace the error-detected parts.
Other materials
Wastegate Valve Closed Position Learning
Description
Wastegate valve closed position learning is a function of ECM to learn the fully closed position of the wastegate valve by monitoring the wastegate valve position sensor output signal. It must be performed under any of the following conditions.
Work Procedure
PERFORM WASTEGATE VALVE CLOS ...
Front Oil Seal
Exploded View
Front output shaft
Front oil seal
Front case
Snap ring
Sprockets with chain
Snap ring
Rear case
: Always replace after every disassembly.
: N·m (kg-m, ft-lb)
: Apply transfer fluid.
: Apply Genuine Liquid Gasket, Lo ...
Intelligent Key Low Battery Warning Does Not Operate
Diagnosis Procedure
CHECK INFORMATION DISPLAY
Check information display.
Refer to Work flow.
Is the inspection result normal?
YES>>
GO TO 2.
NO>>
Repair or replace the malfunctioning parts.
CHECK INTELLIGENT KEY BATTERY
Check Intelligent Key battery.
Refer to Component Inspection.
Is t ...