PERFORM WASTEGATE VALVE CLOSED POSITION LEARNING VALUE CLEAR
With CONSULT
On the CONSULT screen, select “ECM” >> “Work support” >> “WASTEGATE ACTUATOR POSI LEARN VALUE CLEAR”.
Touch “Start”.
Check that “COMPLETED” is displayed. If “COMPLETED” is not displayed, repeat the above.
GO TO 2.
PERFORM NEW CLOSED POSITION LEARNING
With CONSULT
Check that the engine is cold [coolant temperature : 50 °C (122 °F) or less].
On CONSULT screen, select “ECM” >> “Data monitor” >> "Wastegate valve closed position learning bank 1" and "Wastegate valve closed position learning bank 2"
Check that “INCMP” is displayed.
Ignition switch OFF and wait at least 10 seconds.
Ignition switch ON and wait at least 10 seconds.
Is “CMPLT” displayed on CONSULT screen?
YES>>END
NO>>Check that the engine is cold [coolant temperature: 50 °C (122 °F) or less] And then, perform step 3 and 4 again.
Wastegate Valve Closed Position Learning
Idle Air Volume LearningAdditional Service When Replacing Bcm
CAUTION:
When replacing the BCM, always replace it with a new one. The functions controlled by the BCM does not operate properly in case of reuse of the BCM from another vehicle.
When before pairing of BCM and Intelligent Key unit, always writing the BCM configuration. Or not doing so, BCM control f ...
Welding (aluminum)
To repair a crack or a hole in a steel plate, welding is usually used. Either oxygen and acetylene gas welding, arc welding, or brazing is commonly used. For aluminum alloy panels, TIG or MIG welding, which use inert gases (argon gas) as a shield gas, are usually used. This is because aluminum alloy ...
Exploded View
Upper ball seat Steering knuckle Baffle Splash guard Wheel hub and bearing assembly Disc rotor Hub bolt Cotter pin Lower ball seat : Vehicle front : N·m (kg-m, in-lb) : N·m (kg-m, ft-lb) : Always replace after every disassembly. ...