Normal Operating ConditionPrecautions for Removing Battery Terminal
NOTE:
NOTE:
NOTE:
The removal of 12V battery may cause a DTC detection error.
HOW TO DISCONNECT 12V BATTERY TERMINAL
Disconnect 12V battery terminal according to instruction described below.
Open the hood.
Turn ignition switch to the ON position.
Turn ignition switch to the OFF position with the d ...
Inspection
INSPECTION AFTER REMOVAL
When turn the shaft in direction , check returning to direction by spring power.
CAUTION:
The maximum turning force shall be 5 N·m (0.51 kg-m, 44 in-lb).
When turn the shaft in direction , check locking the shaft. INSPECTION AFTER INSTALLATION
ADJUSTMENT AFTER INSTALLATIO ...
Special Service Tools
Tool number
(TechMate No.)
Tool name Description ST25051001
(NI-25695-1)
Oil pressure gauge
Measuring oil pressure
Maximum measuring range: 2,452 kPa (25 kg/cm2, 356 psi)ST25052000
(NI-25695-2)
Hose
Adapting oil pressure gauge to oil pan (upper) KV10115801
(NI-38956)
Oil filter wrench
Removing ...